# HELP python_gc_objects_collected_total Objects collected during gc # TYPE python_gc_objects_collected_total counter python_gc_objects_collected_total{generation="0"} 5.052795e+06 python_gc_objects_collected_total{generation="1"} 598654.0 python_gc_objects_collected_total{generation="2"} 25103.0 # HELP python_gc_objects_uncollectable_total Uncollectable objects found during GC # TYPE python_gc_objects_uncollectable_total counter python_gc_objects_uncollectable_total{generation="0"} 0.0 python_gc_objects_uncollectable_total{generation="1"} 0.0 python_gc_objects_uncollectable_total{generation="2"} 0.0 # HELP python_gc_collections_total Number of times this generation was collected # TYPE python_gc_collections_total counter python_gc_collections_total{generation="0"} 10320.0 python_gc_collections_total{generation="1"} 938.0 python_gc_collections_total{generation="2"} 25.0 # HELP python_info Python platform information # TYPE python_info gauge python_info{implementation="CPython",major="3",minor="12",patchlevel="3",version="3.12.3"} 1.0 # HELP process_virtual_memory_bytes Virtual memory size in bytes. # TYPE process_virtual_memory_bytes gauge process_virtual_memory_bytes 2.15625728e+09 # HELP process_resident_memory_bytes Resident memory size in bytes. # TYPE process_resident_memory_bytes gauge process_resident_memory_bytes 3.1391744e+07 # HELP process_start_time_seconds Start time of the process since unix epoch in seconds. # TYPE process_start_time_seconds gauge process_start_time_seconds 1.78933039623e+09 # HELP process_cpu_seconds_total Total user and system CPU time spent in seconds. # TYPE process_cpu_seconds_total counter process_cpu_seconds_total 2926.63 # HELP process_open_fds Number of open file descriptors. # TYPE process_open_fds gauge process_open_fds 6.0 # HELP process_max_fds Maximum number of open file descriptors. # TYPE process_max_fds gauge process_max_fds 1024.0 # HELP fronius_modbus_up Modbus TCP connection status (1 = up, 0 = down) # TYPE fronius_modbus_up gauge fronius_modbus_up 1.0 # HELP fronius_inverter_info Fronius inverter metadata # TYPE fronius_inverter_info gauge fronius_inverter_info{inverter_serial="34643403",manufacturer="Fronius",model="Primo GEN24 8.0",serial="34643403",version="1.41.11-1"} 1.0 # HELP fronius_smart_meter_info Fronius smart meter metadata # TYPE fronius_smart_meter_info gauge fronius_smart_meter_info{manufacturer="Fronius",meter_model="Smart Meter 63A-1",meter_serial="22180300",model="Smart Meter 63A-1",serial="22180300"} 1.0 # HELP fronius_inverter_ac_power_watts AC active power output (W) # TYPE fronius_inverter_ac_power_watts gauge fronius_inverter_ac_power_watts{inverter_serial="34643403",model="Primo GEN24 8.0"} 532.2 # HELP fronius_inverter_ac_voltage_volts AC output voltage (V) # TYPE fronius_inverter_ac_voltage_volts gauge fronius_inverter_ac_voltage_volts{inverter_serial="34643403",model="Primo GEN24 8.0"} 240.8 # HELP fronius_inverter_ac_current_amperes AC output current (A) # TYPE fronius_inverter_ac_current_amperes gauge fronius_inverter_ac_current_amperes{inverter_serial="34643403",model="Primo GEN24 8.0"} 2.5143 # HELP fronius_inverter_ac_frequency_hertz AC grid frequency (Hz) # TYPE fronius_inverter_ac_frequency_hertz gauge fronius_inverter_ac_frequency_hertz{inverter_serial="34643403",model="Primo GEN24 8.0"} 50.03 # HELP fronius_inverter_ac_apparent_power_va AC apparent power (VA) # TYPE fronius_inverter_ac_apparent_power_va gauge fronius_inverter_ac_apparent_power_va{inverter_serial="34643403",model="Primo GEN24 8.0"} 605.3000000000001 # HELP fronius_inverter_ac_reactive_power_var AC reactive power (VAr) # TYPE fronius_inverter_ac_reactive_power_var gauge fronius_inverter_ac_reactive_power_var{inverter_serial="34643403",model="Primo GEN24 8.0"} -280.32 # HELP fronius_inverter_ac_power_factor AC power factor (-1.0 to 1.0) # TYPE fronius_inverter_ac_power_factor gauge fronius_inverter_ac_power_factor{inverter_serial="34643403",model="Primo GEN24 8.0"} 87.9 # HELP fronius_inverter_dc_power_watts Total DC input power (W) # TYPE fronius_inverter_dc_power_watts gauge fronius_inverter_dc_power_watts{inverter_serial="34643403",model="Primo GEN24 8.0"} 661.0 # HELP fronius_inverter_ac_energy_kwh_total Lifetime total AC energy generation (kWh) # TYPE fronius_inverter_ac_energy_kwh_total counter fronius_inverter_ac_energy_kwh_total{inverter_serial="34643403",model="Primo GEN24 8.0"} 30092.579429999998 # HELP fronius_inverter_operating_state Operating status code (4=MPPT, 2=SLEEPING, 7=FAULT) # TYPE fronius_inverter_operating_state gauge fronius_inverter_operating_state{inverter_serial="34643403",model="Primo GEN24 8.0",state="MPPT"} 4.0 # HELP fronius_battery_soc_percent BYD Battery state of charge (0-100%) # TYPE fronius_battery_soc_percent gauge fronius_battery_soc_percent{inverter_serial="34643403",model="Primo GEN24 8.0"} 75.3 # HELP fronius_battery_available_energy_kwh Available stored energy in battery (kWh) # TYPE fronius_battery_available_energy_kwh gauge fronius_battery_available_energy_kwh{inverter_serial="34643403",model="Primo GEN24 8.0"} 12.4998 # HELP fronius_battery_capacity_kwh_total Nominal total battery energy capacity (kWh) # TYPE fronius_battery_capacity_kwh_total gauge fronius_battery_capacity_kwh_total{inverter_serial="34643403",model="Primo GEN24 8.0"} 16.6 # HELP fronius_battery_max_charge_power_watts Max battery charge power capability (W) # TYPE fronius_battery_max_charge_power_watts gauge fronius_battery_max_charge_power_watts{inverter_serial="34643403",model="Primo GEN24 8.0"} 15360.0 # HELP fronius_battery_charge_limit_percent Battery charge rate limit (%) # TYPE fronius_battery_charge_limit_percent gauge fronius_battery_charge_limit_percent{inverter_serial="34643403",model="Primo GEN24 8.0"} 100.0 # HELP fronius_battery_discharge_limit_percent Battery discharge rate limit (%) # TYPE fronius_battery_discharge_limit_percent gauge fronius_battery_discharge_limit_percent{inverter_serial="34643403",model="Primo GEN24 8.0"} 100.0 # HELP fronius_battery_grid_charging_allowed 1 if grid charging is allowed, 0 otherwise # TYPE fronius_battery_grid_charging_allowed gauge fronius_battery_grid_charging_allowed{inverter_serial="34643403",model="Primo GEN24 8.0"} 0.0 # HELP fronius_dc_channel_power_watts DC channel power (W) # TYPE fronius_dc_channel_power_watts gauge fronius_dc_channel_power_watts{channel="MPPT_1",channel_id="1",inverter_serial="34643403",model="Primo GEN24 8.0"} 4886.0 fronius_dc_channel_power_watts{channel="MPPT_2",channel_id="2",inverter_serial="34643403",model="Primo GEN24 8.0"} 2615.0 fronius_dc_channel_power_watts{channel="StCha_3",channel_id="3",inverter_serial="34643403",model="Primo GEN24 8.0"} 6840.0 fronius_dc_channel_power_watts{channel="StDisCha_4",channel_id="4",inverter_serial="34643403",model="Primo GEN24 8.0"} 0.0 # HELP fronius_dc_channel_voltage_volts DC channel voltage (V) # TYPE fronius_dc_channel_voltage_volts gauge fronius_dc_channel_voltage_volts{channel="MPPT_1",channel_id="1",inverter_serial="34643403",model="Primo GEN24 8.0"} 381.53000000000003 fronius_dc_channel_voltage_volts{channel="MPPT_2",channel_id="2",inverter_serial="34643403",model="Primo GEN24 8.0"} 381.88 fronius_dc_channel_voltage_volts{channel="StCha_3",channel_id="3",inverter_serial="34643403",model="Primo GEN24 8.0"} 329.59000000000003 fronius_dc_channel_voltage_volts{channel="StDisCha_4",channel_id="4",inverter_serial="34643403",model="Primo GEN24 8.0"} 329.59000000000003 # HELP fronius_dc_channel_current_amperes DC channel current (A) # TYPE fronius_dc_channel_current_amperes gauge fronius_dc_channel_current_amperes{channel="MPPT_1",channel_id="1",inverter_serial="34643403",model="Primo GEN24 8.0"} 12.807 fronius_dc_channel_current_amperes{channel="MPPT_2",channel_id="2",inverter_serial="34643403",model="Primo GEN24 8.0"} 6.847 fronius_dc_channel_current_amperes{channel="StCha_3",channel_id="3",inverter_serial="34643403",model="Primo GEN24 8.0"} 20.667 fronius_dc_channel_current_amperes{channel="StDisCha_4",channel_id="4",inverter_serial="34643403",model="Primo GEN24 8.0"} 0.0 # HELP fronius_dc_channel_energy_kwh_total DC channel lifetime energy (kWh) # TYPE fronius_dc_channel_energy_kwh_total counter fronius_dc_channel_energy_kwh_total{channel="MPPT_1",channel_id="1",inverter_serial="34643403",model="Primo GEN24 8.0"} 18559.729190000002 fronius_dc_channel_energy_kwh_total{channel="MPPT_2",channel_id="2",inverter_serial="34643403",model="Primo GEN24 8.0"} 12154.48365 fronius_dc_channel_energy_kwh_total{channel="StCha_3",channel_id="3",inverter_serial="34643403",model="Primo GEN24 8.0"} 2431.28934 fronius_dc_channel_energy_kwh_total{channel="StDisCha_4",channel_id="4",inverter_serial="34643403",model="Primo GEN24 8.0"} 2301.4686 # HELP fronius_smart_meter_power_watts Grid active power (W; >0 export to grid, <0 import from grid) # TYPE fronius_smart_meter_power_watts gauge fronius_smart_meter_power_watts{meter_model="Smart Meter 63A-1",meter_serial="22180300"} 5.89 # HELP fronius_smart_meter_voltage_volts Grid voltage (V) # TYPE fronius_smart_meter_voltage_volts gauge fronius_smart_meter_voltage_volts{meter_model="Smart Meter 63A-1",meter_serial="22180300"} 241.8 # HELP fronius_smart_meter_current_amperes Grid current (A) # TYPE fronius_smart_meter_current_amperes gauge fronius_smart_meter_current_amperes{meter_model="Smart Meter 63A-1",meter_serial="22180300"} 2.064 # HELP fronius_smart_meter_frequency_hertz Grid frequency (Hz) # TYPE fronius_smart_meter_frequency_hertz gauge fronius_smart_meter_frequency_hertz{meter_model="Smart Meter 63A-1",meter_serial="22180300"} 50.0 # HELP fronius_smart_meter_power_factor Grid power factor # TYPE fronius_smart_meter_power_factor gauge fronius_smart_meter_power_factor{meter_model="Smart Meter 63A-1",meter_serial="22180300"} -1.0 # HELP fronius_smart_meter_export_kwh_total Lifetime total energy exported to grid (kWh) # TYPE fronius_smart_meter_export_kwh_total counter fronius_smart_meter_export_kwh_total{meter_model="Smart Meter 63A-1",meter_serial="22180300"} 11762.762 # HELP fronius_smart_meter_import_kwh_total Lifetime total energy imported from grid (kWh) # TYPE fronius_smart_meter_import_kwh_total counter fronius_smart_meter_import_kwh_total{meter_model="Smart Meter 63A-1",meter_serial="22180300"} 17424.998 # HELP fronius_house_load_watts Calculated house electrical load (W) # TYPE fronius_house_load_watts gauge fronius_house_load_watts{inverter_serial="34643403",model="Primo GEN24 8.0"} 526.3100000000001